Electromagnetic FlowmeterYK-LDG

Suitable Medium

Typical application: conductive liquids with strong corrosiveness or impurities such as acids, alkalis, seawater, etc.

Unsuitable Media

Non-conductive liquid/gas

LDG intelligent electromagnetic flowmeter is composed of two parts: sensor and converter. It works based on Faraday's law of electromagnetic induction. It is used to measure the volume flow of conductive liquids with a conductivity greater than 5μS/cm. It is an induction meter for measuring the volume flow of conductive media.

文本细线

Principle

 

According to the principle of Faraday electromagnetic induction, a pair of detection electrodes are installed on the tube wall perpendicular to the axis of the measuring tube and the magnetic line of force. When the conductive liquid moves along the axis of the measuring tube, the conductive liquid cuts the magnetic line of force to generate an induced electric potential. This induced electric potential consists of two The detection electrode detects that the value is proportional to the flow rate, and its value is:


  E=KBVD


   In the formula:


  E-induced electric potential;


  K-coefficient related to magnetic field distribution and axial length;


  B-Magnetic induction intensity;


  V-The average flow velocity of conductive liquid;


  D-electrode distance; (measuring tube inner diameter)


   The sensor uses the induced electric potential E as a flow signal, and transmits it to the converter. After a series of digital processing by amplifying, transforming and filtering, the instantaneous flow and cumulative flow are displayed by a dot matrix liquid crystal with backlight. The converter has 4-20mA output, alarm output and frequency output, and is equipped with communication interfaces such as RS-485, and supports HART and MODBUS protocols.



Features

■ Basic skills


Low frequency square wave excitation, excitation frequency: 1/10 power frequency, 1/16 power frequency, 1/25 power frequency; high frequency square wave excitation, excitation frequency: 1/2 power frequency (for slurry measurement) (optional) ; Excitation current can be selected as 125mA, 187.5mA, 250mA;


Empty tube measurement function without additional electrodes, continuous measurement, fixed value alarm; flow rate measurement range: 0.1 --- 15 m/s, flow rate resolution: 0.5 mm/s; AC high-frequency switching power supply, voltage application range: 85VAC- - 250VAC; DC 24V switching power supply, voltage scope: 16VDC --- 36VDC; network function: MODBUS, HART (optional);


  Chinese and English display mode, (other languages can be customized);


   There are three totalizer totals inside, which can be recorded separately: forward total, reverse total, and difference total.


■ Special function


Power-down time recording function, automatically record the power interruption time of the instrument system, and make up the missing flow; hourly total recording function, record the total flow in hours, suitable for time-sharing measurement system; infrared handheld operation keyboard, remote non All functions of the contact operation converter.


Parameter

Nominal diameter (mm):

(Special specifications can be customized)

Pipeline PTFE lining: DN10~DN600

Pipeline rubber lining: DN65~DN2000

Flow direction:

Positive, negative, net flow

Range ratio:

150:1

Repeatability error:

±0.1% of measured value

Accuracy level:

Pipeline type: Class 0.2, Class 0.5, Class 1.0

Temperature of the measured medium:

Ordinary rubber lining: -20~+60℃

High temperature rubber lining: -20~+90℃

PTFE lining: -30~+120℃

High temperature type PTFE lining: -20~+160℃


Fixed work stress:


(High pressure can be customized)


DN10-DN50:≤4MPa

DN65-DN200:≤1.6MPa

DN250-DN1000:≤1.0MPa

DN1200-DN2000:≤0.6MPa

Flow rate range:

0.1-15m/s

Conductivity range:

Conductivity of measured fluid ≥5μs/cm

Current output:

Load Resistance

0~10mA:0~1.5kΩ

4~20mA:0~750 kΩ

Digital frequency output:

The upper limit of the output frequency can be set within 1~5000HZ with photoelectric isolation transistor open collector bidirectional output. When the external power supply is less than or equal to 35V, the maximum collector current is 250mA when it is turned on

Power supply:

AC220V or DC24V

Length of straight pipe required:

Upstream≥5DN, downstream≥3DN

Connection method:

Flange connection is adopted between the flowmeter and the piping, and the size of the flange connection should meet the requirements of GB11988

Explosion-proof grade:

Exd[ia]IICT5

Protection level:

IP65, up to IP68 for special order

Ambient temperature:

-25~+60℃

Relative humidity:

5%~90%

Total power consumption:

Less than 20W


Other Products

WeChat